3.2 External Control Unit
BU 0200 GB
Subject to technical alterations
53
Controlling the frequency inverter with the ParameterBox
The frequency inverter can only be completely controlled via the ParameterBox if the parameter >Interface<
(P509) is set to the >Control terminal or Keyboard< function (=0) (factory setting) and the inverter is not
enabled via the control terminal.
STOP
Store current frequency
as jog frequency
Press simultaneously:
Set frequency = 0Hz
Increase frequency
Change rotation direction
Decrease frequency
START
Note:
If the frequency inverter is enabled in this mode, then the parameter set is used, which is
selected for this frequency inverter in the Menu >Parameterisation< ... >Basic parameters< ...
under Parameters >Parameter set<.
Attention:
Following the START command, the frequency inverter may start up immediately with a pre-
programmed frequency (minimum frequency P104 or jog frequency P113).
Parameterisation with the ParameterBox
The parameterising mode is entered by selecting the group >Parameterisation< in menu level 1 of the
ParameterBox and confirming this with the OK key. The parameter level of the connected frequency inverter
is now visible.
Press simultaneously:
default settings for this
parameter
Increase parameter value
Reduce parameter value
Open menu group or
save new setting
Press simultaneously:
one level back
Increase menu group
or parameter
Reduce menu group
or parameter
Содержание NORDAC SK 200E
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 35: ...2 Mounting and Installation BU 0200 GB Subject to technical alterations 35...
Страница 60: ...NORDAC SK 200E Manual 60 Subject to technical alterations BU 0200 GB...
Страница 151: ...5 9 Overview of Parameters User defined Settings BU 0200 GB Subject to technical alterations 151...