3.5 Operation screen reference
3
-
58
FRA 51602
■ [ANALYSIS MODE]
: Set the analysis mode.
This sets the analysis processing method (analysis mode) for the measurement data.
○ Setting method
< List operations (confirming) >
• CH1/CH2
: Analyze the CH1 measurement data (ratio) with the CH2 measurement data as the
reference.
• CH2/CH1
: Analyze the CH2 measurement data (ratio) with the CH1 measurement data as the
reference.
• CH1
: Use the CH1 measurement data (amplitude) as it is. The phase is insignificant.
• CH2
: Use the CH1 measurement data (amplitude) as it is. The phase is insignificant.
For more information on the analysis mode, refer to "
5.1 Analysis mode
".
■ [PHASE RANGE]
: Set the phase display range.
This sets the display range for the phase.
○ Setting method
< List operations (confirming) >
• ±180°
: Display phase in the range − 180°
≦
θ < + 180°.
• 0 to +360°
: Display phase in the range 0
≦
θ < + 360°.
• −360 to 0°
: Display phase in the range − 360
≦
θ < 0°.
• UNWRAP
: Phase unwrapping mode.
■ [PHASE RANGE]
–
[APERTURE]
: Set the number of data items (aperture) for the moving average.
This sets the number of moving average phase data points (number of frequency measurements) for
obtaining the group delay characteristic. Although this affects the display of the group delay, it does not
affect the display of phase. The group delay characteristic is smoother when the aperture is increased, but
sudden changes are not observed.
○ Setting method
< Numerical value settings (immediate setting) > , < Numerical value settings (new input) > ,
< Numerical value settings (edit) >
The setting range is the even values from 2 to 200 and the setting resolution is 2.
○ Function key functions
• [DIRECT NEW]
: Set the aperture using the numerical input dialog
【
NUM
】
.
• [DIRECT EDIT]
: Edit the aperture using the numerical input dialog
【
NUM
】
.
Содержание FRA51602
Страница 1: ...NF Corporation GAIN PHASE ANALYZER FRA51602 INSTRUCTION MANUAL OPERATIONS...
Страница 2: ......
Страница 3: ...GAIN PHASE ANALYZER FRA51602 INSTRUCTION MANUAL OPERATIONS DA00061635 001...
Страница 24: ...1 3 Operating principles 1 10 FRA51602 Blank...
Страница 31: ...2 2 Installation 2 7 FRA51602 Figure 2 1 Rack mounting kit assembly diagram JIS...
Страница 32: ...2 2 Installation 2 8 FRA51602 Figure 2 2 Rack mounting kit assembly diagram EIA...
Страница 33: ...2 2 Installation 2 9 FRA51602 Figure 2 3 Rack mounting kit dimensions JIS...
Страница 34: ...2 2 Installation 2 10 FRA51602 Figure 2 4 Rack mounting kit dimensions EIA...
Страница 130: ...3 6 Initial settings 3 92 FRA51602 Blank...
Страница 264: ...9 9 Miscellaneous specifications 9 18 FRA51602 Figure 9 3 External dimensions...
Страница 280: ...XVI FRA51602 Blank...
Страница 282: ......
Страница 284: ......
Страница 285: ......
Страница 286: ...http www nfcorp co jp NF Corporation 6 3 20 TsunashimaHigashi Kohoku ku Yokohama223 8508JAPAN...