6.3
Command Descriptions
EC1000SA
6-26
[SOURce:]SEQuence:TPARameter
This sets the step transition parameters.
The target sequence step must be set in advance by the SEQ:STEP. (
See
“
[SOURce:]SEQuence:STEP”
on page 6-27.)
Use SYST:TUN (
See “
SYSTem:TUNit”
on page 6-43) in advance to set the unit for the
sequence step execution time or query the unit.
When in AC-EXT, AC-SYNC, AC+DC-EXT, or AC+DC-SYNC mode, the step transition
parameter cannot be set. ([3, “Invalid in this mode”] error occurs.)
Syntax:
[SOURce:]SEQuence:TPARameter
<NR2>, <NR1>......
First parameter (step time [s]/[ms])
Type
<NR2>
Range
0.0001 to 999.9999 [s]
0.1 to 999999.9 [ms]
Second parameter (step end phase setting mode)
Type
<NR1>
Range
0 (disable) or 1 (enable)
Third parameter (step end phase [
°
])
Type
<NR2>
Range
0.0 to 359.9
Fourth parameter (step termination)
Type
<NR1>
Range
0 (continue), 1 (end), or 2 (hold)
Fifth parameter (jump step number)
Type
<NR1>
Range
0 (next step), 1 to 255
Sixth parameter (jump times)
Type
<NR1>
Range
0 (infinite times), 1 to 999
Seventh parameter (branch 0)
Type
<NR1>
Range
0 (disabled), 1 to 255
Eighth parameter (branch 1)
Type
<NR1>
Range
0 (disabled), 1 to 255
Command example: SEQ:TPAR 2, 1, 180, 0, 0, 1, 0, 0
Query example:
SEQ:TPAR?
Response example: 2, 1, 180, 0, 0, 1, 0, 0
Содержание EC1000SA
Страница 1: ...NF Corporation PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual nbn Austria GmbH...
Страница 2: ...DA00036667 003 PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual...
Страница 31: ...2 5 Calibration EC1000SA 2 10 2 5 Calibration To calibrate the EC1000SA contact NF Corporation or our agent...
Страница 236: ...6 9 Notes on Remote Control EC1000SA 6 58...
Страница 260: ...8 5 Backup Battery EC1000SA 8 8...
Страница 280: ...9 17 External Dimensions and Weight EC1000SA 9 20...