4.7
Synchronize the Output with External Signal
EC1000SA
4-51
4.7 Synchronize the Output with External Signal
The EC1000SA is equipped with an externally synchronized oscillation function. The software PLL
function synchronizes the output frequency to the frequency of the external synchronization TTL signal.
The output frequency can be synchronized to any frequency from 40 Hz to 500 Hz. The synchronization
phase difference cannot be set.
Select either external signal synchronous (EXT) or line synchronous (LINE) as the external sync signal
source.
When line synchronous is selected, synchronization is with the power source frequency.
Figure 4-15. Synchronized TTL Signal
0
1
Output waveform example
External sync signal (TTL)
Содержание EC1000SA
Страница 1: ...NF Corporation PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual nbn Austria GmbH...
Страница 2: ...DA00036667 003 PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual...
Страница 31: ...2 5 Calibration EC1000SA 2 10 2 5 Calibration To calibrate the EC1000SA contact NF Corporation or our agent...
Страница 236: ...6 9 Notes on Remote Control EC1000SA 6 58...
Страница 260: ...8 5 Backup Battery EC1000SA 8 8...
Страница 280: ...9 17 External Dimensions and Weight EC1000SA 9 20...