3.4
Main Operation Example
EC1000SA
3-30
b) Using setting range limiter
The EC1000SA internal mode (AC-INT, AC+DC-INT) and in external mode (AC-ADD,
AC+DC-ADD) include setting range limiter functions for output voltage and output frequency.
See “5.5.5 Setting range limiter (LIMIT)”
, for details.
Table3-13. Voltage and Frequency Setting Range Limiter
Setting
Setting Range
Resolution
Initial Value
Positive voltage
setting limit
100 V range
+0.1 V to +220.0 V
0.1 V
+220.0 V
200 V range
+0.1 V to +440.0 V
0.1 V
+440.0 V
Negative voltage
setting limit
100 V range
−
220.0 V to
−
0.1 V
0.1 V
−
220.0 V
200 V range
−
440.0 V to
−
0.1 V
0.1 V
−
440.0 V
Frequency upper limit setting limit
1.0 Hz to 550.0 Hz
0.1 Hz
550.0 Hz
Frequency lower limit setting limit
1.0 Hz to 550.0 Hz
0.1 Hz
1.0 Hz
Operation steps
The setting range limit is set via the LIMIT screen under the MISC menu
.
1.
Press the
or
key to move the cursor to the
icon.
ENTER
CANCEL
Cursor
2.
Press the
ENTER
key to display the MISC menu.
Press the
or
to move the cursor key to “LIMIT”.
ENTER
CANCEL
Содержание EC1000SA
Страница 1: ...NF Corporation PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual nbn Austria GmbH...
Страница 2: ...DA00036667 003 PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual...
Страница 31: ...2 5 Calibration EC1000SA 2 10 2 5 Calibration To calibrate the EC1000SA contact NF Corporation or our agent...
Страница 236: ...6 9 Notes on Remote Control EC1000SA 6 58...
Страница 260: ...8 5 Backup Battery EC1000SA 8 8...
Страница 280: ...9 17 External Dimensions and Weight EC1000SA 9 20...