5.5
MISC Menu
EC1000SA
5-30
Table5-22. PROGRAM Screen Items (3/3)
Setting Name
Item
Operation
STEP TERM
Step end
Sets operation after end of step.
Select one of the following three options.
•
CONT: Sequence continuation
•
STOP: Change to Idle mode
•
HOLD: Change to Hold mode
JUMP STEP
Jump step
Sets the step number to jump to after the end of the
previous step.
•
0:
Continue to next step number
•
1 to 255: Jump to specified step number
JUMP NUM
Jump times
Sets the number of times to execute the jump operation
specified by JUMP STEP.
•
0:
Infinite times jump
•
1 to 999: Specified times jump
BRANCH0
Branch step 0
Sets the step number to jump to when trigger input has
occurred.
Two types of branch steps can be set: BRANCH0 and
BRANCH1.
[Command example]
When a STOP is set after a small number of sweeps at the
jump destination step, it enables uses where there is a
safe region for saving data if necessary.
•
0:
Branch disabled
•
1 to 255: Jump to specified step number
BRANCH1
Branch step 1
c) MEMORYM(clears sequence memory)
This clears the sequence memory.
When this cleared, the initial value is input.
See “4.4.5 Clear sequence memory”
.
See “Table3-1. Settings in Memory”
.
Содержание EC1000SA
Страница 1: ...NF Corporation PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual nbn Austria GmbH...
Страница 2: ...DA00036667 003 PROGRAMMABLE AC DC POWER SOURCE EC1000SA Instruction Manual...
Страница 31: ...2 5 Calibration EC1000SA 2 10 2 5 Calibration To calibrate the EC1000SA contact NF Corporation or our agent...
Страница 236: ...6 9 Notes on Remote Control EC1000SA 6 58...
Страница 260: ...8 5 Backup Battery EC1000SA 8 8...
Страница 280: ...9 17 External Dimensions and Weight EC1000SA 9 20...