Grounding Connection
•
Site Link Cables
•
Alarm System Cables
Proper surge protection should be installed on E1/X.21 site links, all antennas and power
inputs to prevent potential damage to the MTS. For more information, please refer to
in
Appendix A, "Field Replaceable Units (FRUs)"
.
For full instructions and guidelines, please refer always to
Motorola Standards
and Guidelines for Communications Sites, R56
.
Grounding Connection
Various cabling from the equipment cabinet to external equipment is made through the MTS Junction Panel
located at the top-rear of the equipment cabinet. The Junction Panel is accessed from the top of the cabinet.
Depending on system con
fi
guration, not all connector locations on Junction Panel are populated.
Cabinet grounding wires may have been installed prior to the cabinet installation. If
so, follow the instructions below.
If grounding wires have not yet been installed, refer to
in
.
Single-point ground method (where each cabinet is grounded to master ground using its own
ground wire) shall be used. The cabinet shall use green (or green-yellow) insulated wire with
a minimum size of 16 mm
2
CSA (#2 AWG) for ground wire.
The MTS is connected to the site ground through the M10 station ground point located on the
junction panel, see
for MTS 2 and
for MTS 4. This connection is essential
for the protection of the equipment against lightning induced surges.
If the speci
fi
ed wire size is not available, use the next-larger available wire size. During the installation of
cabinet ground wires, ensure to check any factory-installed internal ground connections for tightness.
and
depicts the newer version of the MTS Junction Panel.
There may be small differences in older con
fi
gurations.
6802800U74-N September 2009
4-17
Содержание DIMETRA MTS 2
Страница 4: ...This page intentionally left blank ...
Страница 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Страница 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Страница 46: ...Cooling Fans Chapter 1 MTS Overview This page intentionally left blank 1 12 6802800U74 N September 2009 ...
Страница 52: ...Battery Safety Chapter 2 General Safety This page intentionally left blank 2 6 6802800U74 N September 2009 ...
Страница 146: ...Screws Chapter 4 Hardware Installation Figure 4 59 MTS 4 Screws Positions 4 70 6802800U74 N September 2009 ...
Страница 148: ...Screws Chapter 4 Hardware Installation This page intentionally left blank 4 72 6802800U74 N September 2009 ...
Страница 348: ...Base Radio Restoration Chapter 10 Base Radio This page intentionally left blank 10 12 6802800U74 N September 2009 ...
Страница 360: ...PSU TrackID Update Chapter 11 Power Supply Unit This page intentionally left blank 11 12 6802800U74 N September 2009 ...
Страница 474: ...Configuration Chapter 15 Expansion Options This page intentionally left blank 15 44 6802800U74 N September 2009 ...
Страница 476: ...Introduction Chapter 16 MTS 4 Outdoor Enclosure This page intentionally left blank 16 2 6802800U74 N September 2009 ...
Страница 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Страница 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Страница 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...