Service Current Rating
Chapter 3: Site Preparation
rated min. 20 A/55 VDC should be introduced. And for the MTS4, two of these
units should be used, one for each of the two incoming DC lines. Alternatively
for the MTS4, one relay rated 40 A/55 VDC can be used if the two DC lines are
connected to one battery pack. The relays should be controlled in a way that they
disconnect the batteries once the voltage drops below 40.5 V, where the PSU in
the MTS shuts down. Two Motorola kits are available for this purpose:
•
MTS2 LVD RELAY RETROFIT KIT (Kit Number: GMDN2206A)
•
MTS4 LVD RELAY RETROFIT KIT (Kit Number: GMDN2207A)
The battery installation need a short circuit protection closest to the batteries.
The batteries should be installed in the same building and properly ventilated.
Service Current Rating
The input current rating of the DC power supply equipment shall be considered
when selecting the AC main service.
The DC power system has normal loads and start-up loads. These loads are dependent on the number
of Base Radios in the site and the size and condition of the backup battery system. The normal
load of a typical power system is provided in
for several common MTS con
fi
gurations
using battery backup.
lists typical power loads and heat dissipation values for Expansion
Cabinets. These loads may differ for the customer designed power systems.
Table 3-4
Typical Power Loads and Heat Dissipation Values - MTS UHF Configurations
MTS UHF
Configuration
AC
(W)
Heat
AC
(W)
AC
When
Charg-
ing (W)
Heat AC
When
Charging
(W)
DC
-48 V
(W)
Heat
DC
(W)
Comment
TETRA TX 10 W
MTS2 with 1 BR
140
130
520
185
135
125
No combining, low
power PA, no fans
MTS2 with 1 BR w.
Hybrid
165
155
545
210
160
150
Low power PA, no
fans
MTS2 with 2 BRs
245
225
625
280
240
220
Two TX ant., low
power PA, no fans
MTS2 with 2 BRs w.
Hybrid
295
275
675
330
285
265
Low power PA, no
fans
MTS4 with 1 BR w.
MTCC/ATCC
240
230
625
290
235
225
Low power PA,
fans
MTS4 with 2 BRs w.
MTCC/ATCC
375
355
755
410
365
345
Low power PA,
fans
3-16
6802800U74-N September 2009
Содержание DIMETRA MTS 2
Страница 4: ...This page intentionally left blank ...
Страница 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Страница 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Страница 46: ...Cooling Fans Chapter 1 MTS Overview This page intentionally left blank 1 12 6802800U74 N September 2009 ...
Страница 52: ...Battery Safety Chapter 2 General Safety This page intentionally left blank 2 6 6802800U74 N September 2009 ...
Страница 146: ...Screws Chapter 4 Hardware Installation Figure 4 59 MTS 4 Screws Positions 4 70 6802800U74 N September 2009 ...
Страница 148: ...Screws Chapter 4 Hardware Installation This page intentionally left blank 4 72 6802800U74 N September 2009 ...
Страница 348: ...Base Radio Restoration Chapter 10 Base Radio This page intentionally left blank 10 12 6802800U74 N September 2009 ...
Страница 360: ...PSU TrackID Update Chapter 11 Power Supply Unit This page intentionally left blank 11 12 6802800U74 N September 2009 ...
Страница 474: ...Configuration Chapter 15 Expansion Options This page intentionally left blank 15 44 6802800U74 N September 2009 ...
Страница 476: ...Introduction Chapter 16 MTS 4 Outdoor Enclosure This page intentionally left blank 16 2 6802800U74 N September 2009 ...
Страница 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Страница 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Страница 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...