MTS 2 and MTS 4 Installation, Con
fi
guration and Basic Service Manual
Troubleshooting: Power
Troubleshooting: Power
•
Check for Power Supply Unit failure.
•
Verify power (voltage and polarity) on rear connector. If power is present and correct then
replace the Site Controller. Otherwise check for the Site Controller power supply cabling fault.
Ensure that the polarity of DC cable connection is correct, as it is reversed in comparison to MBTS.
Troubleshooting: status sc
This section details usage of the Application mode MMI command
status sc
for general
troubleshooting and to determine the Site Controller status.
Use the status sc command. Observe the “Overall Status”
fi
eld of the resulting output and proceed as follows.
•
If Overall Status = Active – <state> / <reason>, this is an indication that the Site Controller
is currently active, together with the site reference state and the reason for that state.
These states and reasons are explained in
and
.
•
If Overall Status = SC is going active – waiting for BRs, the Site Controller may
be unable to communicate with the BRs. Waiting for Site Controller con
fi
guration
fi
le load, the con
fi
guration
fi
le may be corrupt or is not present. See
and
Table 13-2
Site Reference States - status sc
Site Reference State
Explanation
UNKNOWN
The site reference is initializing - this is a transient state that may persist
for a few minutes at start up.
ENABLED_SYNC
The site reference is fully trained to GPS - This is the highest level of
functionality.
DISABLED
The site reference is not working.
FREE_RUN_SYNC
This is the
fi
rst level of fallback - The site reference will continue to provide
its highest level of service in this state until the free run timer expires.
NON_SYNC
This is the second level fallback - The site reference is providing service
however any feature that needs sites to be synchronized may be impaired.
NON_SYNC_ADJ_REQ
The site has been operating in its 2nd level fallback mode for too long (>
350 days) and should be disabled by the operator.
ENABLED_NON_SYNC
The site has been con
fi
gured to operate in its 2nd level fallback mode (FNC)
to enable start-up without GPS.
6802800U74-N September 2009
13-5
Содержание DIMETRA MTS 2
Страница 4: ...This page intentionally left blank ...
Страница 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Страница 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Страница 46: ...Cooling Fans Chapter 1 MTS Overview This page intentionally left blank 1 12 6802800U74 N September 2009 ...
Страница 52: ...Battery Safety Chapter 2 General Safety This page intentionally left blank 2 6 6802800U74 N September 2009 ...
Страница 146: ...Screws Chapter 4 Hardware Installation Figure 4 59 MTS 4 Screws Positions 4 70 6802800U74 N September 2009 ...
Страница 148: ...Screws Chapter 4 Hardware Installation This page intentionally left blank 4 72 6802800U74 N September 2009 ...
Страница 348: ...Base Radio Restoration Chapter 10 Base Radio This page intentionally left blank 10 12 6802800U74 N September 2009 ...
Страница 360: ...PSU TrackID Update Chapter 11 Power Supply Unit This page intentionally left blank 11 12 6802800U74 N September 2009 ...
Страница 474: ...Configuration Chapter 15 Expansion Options This page intentionally left blank 15 44 6802800U74 N September 2009 ...
Страница 476: ...Introduction Chapter 16 MTS 4 Outdoor Enclosure This page intentionally left blank 16 2 6802800U74 N September 2009 ...
Страница 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Страница 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Страница 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...