Systems X3630 M4 Hot-Swap Rear HDD Drive Cage Option
See the server documentation for detailed instructions for installing this option in the server.
3.5-inch
SAS/SATA
backplane
3.5-inch
hard disk
drive cage
SATA signal cables
LED signal cable
Power cable
1U PCI riser-card
assembly 2
1U PCI riser-card
assembly 1
The option kit contains the following items:
v
One 3.5 inch hard disk drive cage
v
One 3.5 SAS/SATA backplane
v
One LED signal cable
v
Two SATA signal cables
v
One power cable
v
One 1U PCI riser-card assembly 1
v
One 1U PCI riser-card assembly 2
v
IBM warranty information document
v
Important notices document
v
This document
To install the optional rear hot-swap SAS/SATA hard disk drive cage, complete the following steps:
1.
See the server
Problem Determination and Service Guide
for installation guidelines and additional safety
information.
2.
If the server is operating, turn off the server and peripheral devices and disconnect the power cords
and all external cables.
3.
Remove the cover, using the instructions in your server documentation.
4.
If a drive filler cage is installed in the chassis, loosen the screw that secures the drive filler cage to
the chassis; then, rotate the drive filler clockwise and remove the drive filler out of the bay from the
server. Go to step 8.