Grounding Requirements
Chapter 3: Site Preparation
Figure 3-7
Opto-isolated Alarm Input Structure
Grounding Requirements
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
The methods and standards cited in the following paragraphs are typical. Local codes, statutes,
regulations, and/or standards shall supersede any information provided herein, as applicable.
The MTS site must meet certain specifications for adequate protection from
lightning induced transients. Proper ground installation methods are outlined
in the Motorola Standards and Guidelines for Communications Sites, R56. The
references cited earlier in this chapter shall also be followed.
Cabinet grounding wires may have been installed prior to cabinet installation. If
so, follow the instructions below.
Single-point ground method (where each cabinet is grounded to master ground using its own
ground wire) shall be used. Equipment cabinet shall use green (or green-yellow) insulated wire
with a minimum size of 16 mm
2
CSA (6 AWG) for ground wire.
Any external -48 VDC power system should be grounded in accordance with manufacturer’s
instructions and any applicable local regulations.
3-22
6802800U74-N September 2009
Содержание DIMETRA MTS 2
Страница 4: ...This page intentionally left blank ...
Страница 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Страница 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Страница 46: ...Cooling Fans Chapter 1 MTS Overview This page intentionally left blank 1 12 6802800U74 N September 2009 ...
Страница 52: ...Battery Safety Chapter 2 General Safety This page intentionally left blank 2 6 6802800U74 N September 2009 ...
Страница 146: ...Screws Chapter 4 Hardware Installation Figure 4 59 MTS 4 Screws Positions 4 70 6802800U74 N September 2009 ...
Страница 148: ...Screws Chapter 4 Hardware Installation This page intentionally left blank 4 72 6802800U74 N September 2009 ...
Страница 348: ...Base Radio Restoration Chapter 10 Base Radio This page intentionally left blank 10 12 6802800U74 N September 2009 ...
Страница 360: ...PSU TrackID Update Chapter 11 Power Supply Unit This page intentionally left blank 11 12 6802800U74 N September 2009 ...
Страница 474: ...Configuration Chapter 15 Expansion Options This page intentionally left blank 15 44 6802800U74 N September 2009 ...
Страница 476: ...Introduction Chapter 16 MTS 4 Outdoor Enclosure This page intentionally left blank 16 2 6802800U74 N September 2009 ...
Страница 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Страница 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Страница 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...