CHAPTER 3.0 Wiring and Installation
3-39
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
3.10.2.3 Size
C
PE
PE (J7.4)
M o t o r
U2 (J7.1)
V2 (J7.2)
g r o u n d i n g o f s h i e l d
v i a c o n n e c t o r c l a m p
W2 (J7.3)
V
W
U
grounding of shield
via connector clamp
(or RF connection to
ground screw in
case of terminal board)
J7
DS2110 C
Figure 3.32 DS2110 C Motor Power Connection
-
Fixed connector: 4 pins, male connector
-
Mating connector, 4 pins, female, crimped supplied with the drive. (Molex 42816-0412)
-
C size wiring: cable 8 AWG (8.4 mm
2
).
-
Pos. Name Function
J7.4
PE
Motor Protective Earth
J7.3 W2
Motor
Phase
W
J7.2 V2
Motor
Phase
V
J7.1 U2
Motor
Phase
U
Table 3. -17 J7, Motor connector, C Size