CHAPTER 3.0 Wiring and Installation
3-21
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
3.5.1 Drive Contactor (User Supplied)
A contactor (suitably rated for the particular DS2110) should be installed just before the AC input line filter of the
DS2110. The contactor acts as a remote switch that may cut off the AC mains supply in the event of an
emergency shutdown. This contactor should be sized based on the continuous power of the system.
3.5.2 Wiring notes for J6, J7, J9 connectors (Size C)
The connectors used on the DS2110 Size C are formed using crimp terminals. The appropriate crimps (Molex
type 42815-0031) are supplied together the floating connectors for J6, J7, and J9. These crimps are sized for an 8
AWG (8.4 mm
2
) cable with a 10 mm wire stripping. It is recommended to use the appropriate Molex crimping tool
(63814-0000, or 63811-1500, or equivalent). After crimping, the contact must be inserted into the floating
connector with the correct orientation and should be held in position by the TPA (Terminal Position Assurance)
jumper, as shown in Fig 3.15.
Figure 3.15 DS2110 Size C Crimp Assembly
CAUTION - All external electrical wiring connected to this equipment
must be color coded in accordance with European Standard EN
60204-1 requirements.
CAUTION - All wires and cables entering and leaving the IP54 rated
enclosures or cabinets containing the DS2110 Servo-drive and the
Regen resistor(s) must be protected and anchored in accordance with
the requirements of EN 60204-1.
CAUTION - Additional electromagnetic compatibility (EMC) measures
which must be installed on equipment cables associated with the
DS2110 Servo-drive are given in Chapter 2 of this User’s Guide.
Required for
CE-Compliance
Содержание DS2110
Страница 15: ...CHAPTER 1 0 Overview 1 11 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 192: ...CHAPTER 5 0 Functional Overview 5 70 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 261: ...APPENDIX B GUI B 63 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...
Страница 266: ...APPENDIX B GUI B 68 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 310: ...APPENDIX G ETHERNET MEZZANINE CARD G 9 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...