APPENDIX B – GUI
B-18
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
B.2.16.13 Limiting
Status
The Limiting Status panel allows the user to see whether any limiting is active
•
Thermal Limiting
→
(ON/OFF)
•
Manual Mode Limiting
→
(ON/OFF)
•
I2T Limiting
→
(ON/OFF)
B.2.16.14 Current
Loop
The Current Loop panel allows the user to set/read the current loop compensator configuration and to monitor
some internal loop variables.
The current control consists of a pair of compensators, one for the q-axis current control and the other for d-axis
current control. The feedback currents ‘current_q-axis_observer’ and ‘current_d-axis_observer’ are output from
the predictive current state observers.