APPENDIX B – GUI
B-52
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
B.2.16.59 Drive Status Byte 4
DRIVE STATUS BYTE 4 :
•
Phase A Current Offset
→
Indicates if the DSP phase A current offset is greater than a programmable limit.
•
Phase B Current Offset
→
Indicates if the DSP phase B current offset is greater than a programmable limit.
•
Motor Thermal Warning
→
indicates that the motor winding temperature is within 10% of the motor max
temperature.
•
Bridge Thermal Warning
→
Indicates that the power transistor heatsink temperature is within 10% of the
bridge maximum temperature.
•
Regen Warning
→
Indicates that the power dissipated in the regen resistor(s) is within 10% of the continuous
capability of the resistor(s).
•
Limit Switch hit Warning
→
Indicates that either clockwise or counter-clockwise limit switch has become
active.
B.2.16.60 Drive Status Byte 5
DRIVE STATUS BYTE 5 :
•
Model Initialization fault
→
Indicates the model has failed either the initialization function or parameter access.
•
Model Run fault
→
Indicates the model has returned an error while running.
•
Model Programming fault
→
Indicates a programming error in the model.
Содержание DS2110
Страница 15: ...CHAPTER 1 0 Overview 1 11 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 192: ...CHAPTER 5 0 Functional Overview 5 70 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 261: ...APPENDIX B GUI B 63 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...
Страница 266: ...APPENDIX B GUI B 68 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 310: ...APPENDIX G ETHERNET MEZZANINE CARD G 9 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...