CHAPTER 2.0 Safety & EMC Instructions
2-13
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
Shielded cable is required to be installed by the user for many external user cable connections to the DS2110.
Details of areas where shielded cable must be installed and details of earthing arrangements which must be
implemented for the shields of such cables are given throughout Section 3 of this User’s Guide.
2.3.2
Recommended EMC Filters
No internal filtering is provided in the DS2110. To ensure EMC compliance an external line filter must be installed.
The recommended filters for the DS2110 are detailed below.
DS2110 µA Size
Moog
Order Code
Manufacturer Rated
Current
(A)
@ 50
o
C (40
o
C)
Max Voltage
Drive Input
-
Schaffner Fairite Clamp.
Part # 00443164151
- -
24V
dc
Input
(4 Turns in Common Mode)
AT6009
Schaffner FN 258-7/07
7 (8.4)
3x480V
3-phase AC Line Input
-
Schaffner FN 350-12/29
12 (13.8)
1x250V
1-phase AC Line Input
(µA 3/11 only)
DS2110 A,B,C,D, E Sizes
Moog
Order Code
Manufacturer Rated
Current
(A)
@ 50
o
C (40
o
C)
Max Voltage
Drive Input\Size
AT6017
1
Schaffner FN2070-3-06
(3)
250V
24V
dc
Input
AT6009
Schaffner FN258-7/07
7 (8.4)
3x480V
3-phase AC Line Input
(Size A)
AT6010
Schaffner FN258-16/07
16 (19.2)
3x480V
3-phase AC Line Input
(Size B)
AT6011
Schaffner FN258-30/07
30 (36)
3x480V
3-phase AC Line Input
(Size C)
AT6012
Schaffner FN258-42/07
42 (50.4)
3x480V
3-phase AC Line Input
(Size D 50/140)
AT6013
Schaffner FN258-55/07
55 (66)
3x480V
3-phase AC Line Input
(Size D 60/180)
AT6015
Schaffner FN258-100/35
100 (113)
3x480V
3-phase AC Line Input
(Size D 100/300)
Table 3 - Recommended EMC Filters for DS2110
1
The 24Vdc filter can be used with two DS2110 drives. If more than two DS2110 drives are in use on a machine, a filter
from the same series can be used with a higher current rating.
This equipment intended to be connected to an industrial low-voltage power supply network, or public network,
which does not supply buildings used for domestic purposes (second environment, according to EMC Standards).
If connected to a low-voltage public network that supplies domestic premises (first environment), this product is
expected to cause radio interference in which case supplementary measures may be required.
Содержание DS2110
Страница 15: ...CHAPTER 1 0 Overview 1 11 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 192: ...CHAPTER 5 0 Functional Overview 5 70 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 261: ...APPENDIX B GUI B 63 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...
Страница 266: ...APPENDIX B GUI B 68 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 310: ...APPENDIX G ETHERNET MEZZANINE CARD G 9 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...