APPENDIX B – GUI
B-34
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
B.2.16.33 Resolver
Parameters
The Resolver Parameters panel allows the user to set the parameters of this motor position feedback sensor.
•
Resolver Poles
→
The number of resolver poles.
•
Resolver Transformer Turns Ratio
→
A physical characteristic of the resolver, which determines the amplitude
of the resolver reference.
•
Resolver reference amplitude
→
This is the voltage output from the DS2110 to drive the resolver.
•
Resolver position
→
The multi-turn position derived from the resolver input position and used as feedback in
the position loop if resolver position is selected for the position loop feedback
•
Resolver commutation position
→
The electrical angle of the resolver. Depending on the pole count of the
resolver this value is proportional to the mechanical angle.
Содержание DS2110
Страница 15: ...CHAPTER 1 0 Overview 1 11 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 192: ...CHAPTER 5 0 Functional Overview 5 70 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 261: ...APPENDIX B GUI B 63 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...
Страница 266: ...APPENDIX B GUI B 68 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 310: ...APPENDIX G ETHERNET MEZZANINE CARD G 9 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...