APPENDIX B – GUI
B-29
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
B.2.16.27 Regen
Parameters
The Regen Parameters panel allows the user to see and set the regeneration parameters.
The regeneration control is implemented to prevent the capacitor over voltage caused by the energy that returns
back into the D.C. Bus during a rapid motor deceleration or an overhauling load.
To prevent it, a shunt regulator circuit senses when the bus voltage exceeds the Regeneration cut-in voltage and
switches a Regeneration resistor across the D.C. Bus, to dissipate the Regeneration energy.
REGENERATION PARAMETERS :
•
Regen control mode
→
Allows user to select between:
9
No Regen
9
Duty-cycle
9
Duty-cycle + fault
9
Power fault only
9
Power warning only
•
Regen-On Voltage (V)
→
The regeneration transistor turn-on voltage.
•
Regen-Off Voltage (V)
→
The regeneration transistor turn-off voltage.
•
Regen Power (W)
→
The average regeneration power (measured).
•
Max. Regen Current (A)
→
The maximum regeneration current.
•
Regen Power Capability (W)
→
The total regeneration power capability.
Содержание DS2110
Страница 15: ...CHAPTER 1 0 Overview 1 11 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 192: ...CHAPTER 5 0 Functional Overview 5 70 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 261: ...APPENDIX B GUI B 63 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...
Страница 266: ...APPENDIX B GUI B 68 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 310: ...APPENDIX G ETHERNET MEZZANINE CARD G 9 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...