CHAPTER 5.0 Functional Overview
5-30
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
5.10.1.2
Digital Input Debounce Count
The count for all digital input is by default set to 1. The digital inputs are checked at a fixed rate (every 2ms). By
setting the count to a higher value, the handler function will only be called, when the input is seen to have settled
at a level, for the defined number of counts, each time it is checked.
5.10.1.3
Digital Input Invert Input
This parameter invert the logic associated with a digital input handler function. Default operation for each handler
function was listed earlier. If the invert option is set, it will invert this logic. By default the invert option is not set.
For example, the default operation of the automatic/manual input is to set the drive into manual mode if the input
is cleared, and into automatic mode if the input is set. By setting the invert parameter for this input, it will set the
drive into automatic mode if the input is cleared, and into manual mode if the input is set.
5.10.1.4
Digital Input Status Word
The digital input status word shows the state of the 8 bits of the digital input word. The LSB corresponds to I1,
and the MSB corresponds to I8. A bit is shown as 1, if the digital input is set, and shown as 0, if the digital input is
cleared. This is the case regardless of the invert option being set.
5.10.2 Digital Output Functionality
There are 3 digital outputs on the DS2110, numbered O1 to O3 on the DS2110 front-panel. All 3 outputs are
user-configurable. The user can configure: -
•
The bits within a specific parameter that is to be associated with the digital output. This is performed by
setting the parameter field number and a mask to select specific bits.
•
Invert the logic of the digital output, such that if the selected bit is set, the output is cleared and vice
versa.
The parameters associated with outputs are listed below. Note that the names of the parameters, and the
numbers on the front-panel both start at 1: -
Field
Number
Type Name
1561 U16
digital_output_1_field_number
1562 U32
digital_output_1_mask
1563 U08
digital_output_1_invert
1564 U16
digital_output_2_field_number
1565 U32
digital_output_2_mask
1566 U08
digital_output_2_invert
1567 U16
digital_output_3_field_number
1568 U32
digital_output_3_mask
1569 U08
digital_output_3_invert
Table 5.19 List of Digital Output Parameters
Содержание DS2110
Страница 15: ...CHAPTER 1 0 Overview 1 11 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 192: ...CHAPTER 5 0 Functional Overview 5 70 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 261: ...APPENDIX B GUI B 63 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...
Страница 266: ...APPENDIX B GUI B 68 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 310: ...APPENDIX G ETHERNET MEZZANINE CARD G 9 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...