CHAPTER 3.0 Wiring and Installation
3-55
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
3.13 Wiring Summary
3.13.1 µA Size Power Stage
-
Fixed connector: 12 pins, male connector
-
Mating connector, 12 pins, female, supplied with the drive. Phoenix Combicon (Part # GMSTB 2.5/12-ST-
7.62)
-
µA size wiring: cable 14 AWG (2.1 mm
2
). Wire stripping: 7 mm.
-
Tightening torque: 0.5Nm.
Pos. Name Function
J6.1
DC-
DC Bus (-)
J6.2
DC+
DC Bus (+)
J6.3 RR
Regeneration
Resistance
J6.4
L1
Phase "L1", three-phase voltage input 230/460Vac
±
10%
J6.5 L2
Phase "L2", ", three-phase voltage input 230/460Vac
±
10%
J6.6 L3
Phase "L3", ", three-phase voltage input 230/460Vac
±
10%
J6.7
PE
Motor Protective Earth
J6.8 W
Motor
Phase
W
J6.9 V
Motor
Phase
V
J6.10 U
Motor
Phase
U
J6.11
24V
+24V Logic Backup Supply
J6.12
0V
Logic Supply Return
-
PE Stud wiring: cable 6 AWG (13mm
2
)
Pos. Name Function
PE
PE
Protective Earth Stud on Chassis
Содержание DS2110
Страница 15: ...CHAPTER 1 0 Overview 1 11 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 192: ...CHAPTER 5 0 Functional Overview 5 70 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 261: ...APPENDIX B GUI B 63 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...
Страница 266: ...APPENDIX B GUI B 68 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 310: ...APPENDIX G ETHERNET MEZZANINE CARD G 9 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...