APPENDIX B – GUI
B-24
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
B.2.16.21 Generic
Filters
The Generic Filters panel allows the user to set the 9 programmable parameters of the filter on the output of the
velocity compensator.
It may be configured as hi-pass, low-pass, band-pass or band-stop, to allow for maximum flexibility.
The filter is used in the velocity loop and the output of the velocity compensator becomes the input to the generic
filter.
GENERIC FILTER PARAMETERS :
•
Filter Coefficients
→
these can be set individually or else the filter coefficient calculator can be used to derive
the coefficients for a requested filter response.
•
Filter Mode
→
Allows the user to choose the filter mode between high/low pass and band pass/stop. This is
used in the drive to reduce the amount of calculation performed when high/low pass is selected.
The ‘Calculator’ button starts the filter coefficient calculator
The ‘Update from calculator’ button will place the values calculated by the filter coefficient calculator into the filter
coefficient boxes ready to write to the drive. They will not be written to the drive until explicitly requested.
Содержание DS2110
Страница 15: ...CHAPTER 1 0 Overview 1 11 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 192: ...CHAPTER 5 0 Functional Overview 5 70 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 261: ...APPENDIX B GUI B 63 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...
Страница 266: ...APPENDIX B GUI B 68 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 310: ...APPENDIX G ETHERNET MEZZANINE CARD G 9 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...