CHAPTER 5.0 Functional Overview
5-24
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
5.8 Position
Feedback
The feedback signal for the position loop closure can be derived from the resolver input or the encoder input.
5.8.1 Position
Feedback Configuration
5.8.1.1
Position feedback
The selection of the position feedback is done through parameter
position_feedback
(Field Number 1168). It can
have the following values:
1
-
position feedback from resolver
2
-
position feedback from encoder
See 'Resolver Module' and 'Encoder Module' for further information on how to set up resolvers and encoders.
5.8.2 Position feedback parameters
position_feedback
Data type
unsigned 8-bit
Access
read / write
Default value
1
Minimum value
1
Maximum value
2
Storage type
customer settings eeprom
Data group
application parameter
Field number
1168