CHAPTER 3.0 Wiring and Installation
3-52
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
3.11.2.1 Drive
Ready
Relay
The DS2110 provides 1 relay output on connector J2C. This relay closes when the drive is ready and no faults
are present.
-
Fixed connector: 2 pins, male connector
-
Mating connector, 2 pins spring cage, female, supplied with the drive. Phoenix Contact (Part # FK-MC 0.5/2-
ST-2.5)
-
Wiring: cable. 28-20AWG (0.14-0.5mm
2
)
-
Wire stripping: 8 mm
Pos. Name Function
J2C.1
Drive Ready 1
Drive ready relay contact pin 1 Drive Ready Relay Contact
J2C.2 Drive
Ready
2
Drive
ready relay contact pin 1 Drive Ready Relay Contact
Table 3. -26 J2B, DS2110 Digital Output connector
The following electrical description applies to the Drive ready relay of the DS2110.
J2C.1
Drive Ready 1
Drive Ready
Relay
J2C.2
Drive Ready 2
5V
Figure 3.45 Drive Ready Relay Output
Note that:-
Closed
when drive ready and no faults.
Max
. voltage 36 V
Max
. contact current 100 mA