CHAPTER 4.0 Getting Started
4-15
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
4.15 Oscilloscope
4.15.1 Oscilloscope Set-up
Open the oscilloscope,
“DS2110
→
Oscilloscope”
The Status prompt in the lower right hand corner should be yellow and read “
initializing”
Set-up Channels 1-3, Timebase and Trigger as per the table 1 below,
Figure 4.14 Oscilloscope
Channel 1
Channel 2
Channel 3
Timebase
Trigger
Status
Visible
Visible
Visible
------------
------------
Source
Demand
Velf
Iqact
------------
Demand
Scaling
200000000 / div
20 / div
5 A / div
0.002 s / div
------------
Delay
------------
------------
------------
------------
Delay - 0.002 s
Coupling
------------
------------
------------
------------
DC
Slope
------------
------------
------------
------------
Rising
Mode
------------
------------
------------
------------
Single
Table 4.1 Oscilloscope Channel Set-up