CHAPTER 4.0 Getting Started
4-7
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
For drives equipped with an internal Regeneration resistor, the parameters associated with that resistor must be
set. If the drive has external regeneration capability, all regeneration resistor parameters are set to zero. The drive
will display a fault (F3) and will not enable until suitable parameters for regeneration resistors are entered and
saved. The resistance and power rating of the regeneration resistor connected to the drive should be entered in
either the “
External Regen” or “Internal Regen”
window.
Open
“
Drive Setup
→
Regen Resistor
→
External Regen”
and enter the correct resistance and power ratings
for the externally connected Regen Resistor (RR).
Select Write All.
Confirm that values are correct.
Figure 4.6 External Regen Parameters
The software also checks the value of regeneration resistance entered. If too low a value is entered, such that the
current that would flow on turn-on of the regeneration transistor exceeds the ratings of the regeneration,
transistor, a fault (F3) is also reported.
The drive will also display an F3 if the user inputs data for a regeneration resistor such that the current, which
would flow in the regeneration transistor on turn on, is greater than the Max RR Current level set in the GUI
panels “
DS2110
→
Drive Setup
→
Regen Resistor
→
Regen Parameters”
.
Содержание DS2110
Страница 15: ...CHAPTER 1 0 Overview 1 11 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 192: ...CHAPTER 5 0 Functional Overview 5 70 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 261: ...APPENDIX B GUI B 63 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...
Страница 266: ...APPENDIX B GUI B 68 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 310: ...APPENDIX G ETHERNET MEZZANINE CARD G 9 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...