APPENDIX B – GUI
B-22
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
B.2.16.18 Nominal Bus Voltage
The Nominal Bus Voltage panel allows the user see the nominal value of the DC bus voltage.
NOMINAL BUS VOLTAGE:
Bus Voltage (nominal) (V)
→
The nominal value of the bus voltage. If measured bus voltage is selected then
this value is measured once the bus voltage is stable, otherwise this is the default bus voltage
B.2.16.19 Softstart Voltage Parameters
The Softstart panel allows the user to enable/disable the softstart detection and to set the softstart parameters.
Softstart is used to limit the inrush current to the d.c. bus capacitor bank on application of a.c. mains power.
Softstart will only occur if the DC bus voltage level is above the softstart lower limit.
SOFTSTART VOLTAGE PARAMETERS :
•
Softstart Detection Completed
→
Shows whether the softstart detection has been completed.