CHAPTER 5.0 Functional Overview
5-9
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
5.4.4 Feedback and Commutation Parameters
Different sources for the feedback of motor position to the controller are available. The following table lists these
options. In the case where no encoder is used (i.e. comfbk = 1), then the encoder parameters may not need to be
set. The resolver reference amplitude is in units of 32768/2V, Typically the default value for the resolver’s
reference amplitude is used. The number of resolver poles is required regardless of the feedback source. The
values for encoder set-up are listed in the encoder section, and are summarised in the table below: -
Field No.
Type
Units
Motor Database Name
Name
1042 U16
none
DS2110_rref
resolver_amplitude
1035 U08
none
DS2110_comfbk
commutation_feedback
1036 S16
none
DS2110_comofs
commutation_offset
1037 U16
none
Pr
resolver_poles
1704 U08
none
DS2110_encsup
encoder_supply
1705 U08
none
DS2110_enctyp
encoder_type
1706 U32
none
encinc
encoder_number_of_increments
1709 U08
none
ssibit
encoder_ssi_number_bits
1710 U08
none
DS2110_ssicod
encoder_ssi_coding
1711 U32
none
DS2110_ssimsk
encoder_ssi_data_bit_mask
Table 5.8 List of motor (Feedback and Commutation) parameters
5.4.5 Bus
Parameters
The default value for the bus over-voltage limit is 800, with defaults of 760 and 780 for the regen. off and on limit
respectively.
Field No.
Type
Units
Motor Database Name
Name
1233 F32
V Vmax
bus_over_voltage_limit
1248 F32
V Vrgnoff
regen_off_voltage
1249 F32
V Vrgnon
regen_on_voltage
Table 5.9 List of motor (Bus) parameters
5.4.6 Motor Thermal Parameters
The coefficients that characterize the NTC of the motor, must be set for each motor. The temperature and span at
which the current is foldback as a function of motor temperature, can also be set, along with the maximum
temperature allowed for the motor. Thermal foldback is only possible where a NTC is present in the motor.
The motor thermal limiting is enabled by default, so the user should not modify the current limit mask setting.
Field No.
Type
Units
Motor Database Name
Name
1385 F32
none
DS2110_ntca0
motor_sensor_coefficient_a0
1386 F32
none
DS2110_ntca1
motor_ sensor _coefficient_a1
1387 F32
none
DS2110_ntca2
motor_ sensor _coefficient_a2
1388 F32
none
DS2110_ntca3
motor_ sensor _coefficient_a3
1389 F32
°C DS2110_ntcmin
motor_ sensor _min_temperature
1390 F32
°C DS2110_ntcmax
motor_ sensor _max_temperature
1135 U16
none
DS2110_tlmena
current_limit_mask
1404 F32
°C Tmax
motor_maximum_temperature
1405 F32
°C DS2110_tlmstt
thermal_limit_motor_start_temperature
1406 F32
°C DS2110_tlmspn
thermal_limit_motor_span_temperature
Table 5.10 List of motor (thermal) parameters
Содержание DS2110
Страница 15: ...CHAPTER 1 0 Overview 1 11 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 192: ...CHAPTER 5 0 Functional Overview 5 70 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 261: ...APPENDIX B GUI B 63 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...
Страница 266: ...APPENDIX B GUI B 68 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 310: ...APPENDIX G ETHERNET MEZZANINE CARD G 9 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...