CHAPTER 3.0 Wiring and Installation
3-5
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
3.2 Equipment Mounting
This section details the mechanical dimensions of the DS2110 chassis, as well as required clearances for cabling
etc. The DS2110 is designed to be panel or cabinet mounted. The DS2110 must be mounted in a vertical
orientation. The DS2110 must be panel mounted within an enclosure or cabinet that provides a degree of ingress
protection against liquids and objects of at least IP54. Such enclosures or cabinets must be accessible to
technically qualified service or maintenance persons only. It is recommended that the cabinet be ventilated using
filtered or conditioned air, free of corrosive or electrically conductive contaminants. The accumulation of dust, dirt,
etc. on the equipment must be avoided. A minimum clearance above and below each of the DS2110 drive sizes is
required. These distances are detailed in Table 3.
-1
.
DS2110 Size
Minimum Clearance Top
(mm)
Minimum Clearance
Bottom (mm)
µA & A
60
100
B 60 100
C 80 160
D 100 200
E 200 300
Table 3. -1 Minimum Clearance around DS2110 Drives
If any of the DS2110 units are mounted in a closed cabinet, allow 100mm clearance at the front for cable bends.
Содержание DS2110
Страница 15: ...CHAPTER 1 0 Overview 1 11 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 192: ...CHAPTER 5 0 Functional Overview 5 70 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 261: ...APPENDIX B GUI B 63 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...
Страница 266: ...APPENDIX B GUI B 68 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL Page Intentionally Blank...
Страница 310: ...APPENDIX G ETHERNET MEZZANINE CARD G 9 CDS7324 FORMERLY LSF 0819 Rev A INSTALLATION USER S MANUAL...