CHAPTER 10 DEDICATED INSTRUCTIONS
10
10.
17 G
P
.C
C
PAS
ET
(Set
ting Param
e
te
rs)
10.
17.
1
P
rocedure
fo
r s
e
ttin
g param
et
e
rs
using t
he C
C
PA
SET
inst
ru
ct
ion
• Setting parameters for local stations
5.
Create a CCPASET instruction program. (
Page 371, Section 10.17.2 (4))
6.
Write PLC parameters and programs to the CPU module through GX Works2.
[Online]
[Write to PLC]
7.
Data link is stopped during in execution. (
If some instruction is executed while data link processing, malfunction may be caused due to a change in
the link device assignment.
8.
Execute the CCPASET instruction.
(2) Parameters that cannot be set using the CCPASET instruction
The following table shows the parameters that cannot be set using the CCPASET instruction. The master/local
module operates with the setting status listed below.
(a) Parameters that cannot be set to the master station and submaster station
Set the parameters listed above using the network parameters in GX Works2.
Item
Description
Setting range
Switch 1
Enter the network number.
0001
H
to 00EF
H
Switch 2
Enter the station number.
3101
H
to 3178
H
(Station number: 1 to
120)
31FF
H
(Set a station number using the
UINI instruction.)
Switch 3
Enter "0000
H
".
0000
H
(Fixed)
Switch 4
Switch 5
Item
Setting status
Network setting
Mode
Online (Normal Mode)
Network Configuration
Settings
Alias
Not set
Comment
Block Data Assurance per
Station
Not set
Network Operation
Settings
Parameter Name
Not set
Refresh Parameters
Not set
Since link refresh cannot be performed, use direct access to directly access the
link device.
Interrupt Settings
Not set (Interrupts cannot be performed.)
Interlink Transmission Parameters
Not set (Interlink transmission cannot be performed.)
Routing Parameters
Not set
Transient transmission that requires routing parameters cannot be performed.
For whether routing parameters are needed, refer to the following.
0
0
H
Network No.: 01
H
to EF
H
(1 to 239)
1
3
H
Station number: 01
H
to 78
H
(1 to 120)
Use the UINI instruction to set the station number.: FF