477
APPENDICES
A
Appendix
3
Link Spec
ial
Relay (SB
) Li
st
SB004E
Own station master/
submaster function
operation status
Stores if the own station is operating as a submaster station.
OFF: Operates as a master station (master operating station)
ON: Operates as a submaster station (submaster operating station)
(Conditions)
This is enabled when either of the following conditions is met.
• Station setting (own station) (1) (SB0044) is on.
• Both Station setting (own station) (1) (SB0044) and Station setting
(own station) (2) (SB0045) are off.
×
SB004F
Station number status
of the operating station
Whether the set station number has been set using GX Works2 or the
UINI instruction is stored.
OFF: Operating with the station number set using GX Works2
ON: Operating with the station number set using the UINI instruction
×
SB0050
Link start request
accept status (own
station)
Turns on when a cyclic transmission start request by Link start (own
station) (SB0000) is accepted.
OFF: Not accepted (SB0000 is off.)
ON: Start accepted (SB0000 is on.)
(Condition)
• This is enabled when Baton pass status (own station) (SB0047) is off.
SB0051
Link start completion
status (own station)
Turns on when Link start request accept status (own station) (SB0050)
turns on, and cyclic transmission start is completed.
OFF: Start not completed (SB0000 is off.)
ON: Start completed (SB0000 is on.)
(Condition)
• This is enabled when Baton pass status (own station) (SB0047) is off.
SB0052
Link stop request
accept status (own
station)
Turns on when a cyclic transmission stop request by Link stop (own
station) (SB0001) is accepted.
OFF: Not accepted (SB0001 is off.)
ON: Stop accepted (SB0001 is on.)
(Condition)
• This is enabled when Baton pass status (own station) (SB0047) is off.
SB0053
Link stop completion
status (own station)
Turns on when Link stop request accept status (own station) (SB0052)
turns on, and cyclic transmission stop is completed.
OFF: Stop not completed (SB0001 is off.)
ON: Stop completed (SB0001 is on.)
(Condition)
• This is enabled when Baton pass status (own station) (SB0047) is off.
SB0054
System link start
request accept status
Turns on when a cyclic transmission start request by System link start
(SB0002) is accepted.
OFF: Not accepted (SB0002 is off.)
ON: Start accepted (SB0002 is on.)
(Condition)
• This is enabled when Baton pass status (own station) (SB0047) is off.
(Master
operating
station only)
×
Number
Name
Description
Availability
Master
station
(submaster
station)
Local
station
Содержание QJ71GF11-T2
Страница 1: ...MELSEC Q CC Link IE Field Network Master Local Module User s Manual QJ71GF11 T2 ...
Страница 2: ......
Страница 558: ...556 Appendix 12External Dimension Diagram 27 4 23 115 98 4 Unit mm ...
Страница 559: ...557 APPENDICES A Appendix 12 External Dimension Diagram Memo ...
Страница 567: ......