![Mitsubishi Electric QJ71GF11-T2 Скачать руководство пользователя страница 153](http://html.mh-extra.com/html/mitsubishi-electric/qj71gf11-t2/qj71gf11-t2_user-manual_1811847153.webp)
151
CHAPTER 8 FUNCTIONS
8
8.
3
IP
Pac
ket
T
ransf
e
r F
u
n
cti
on
8.
3.
2
How t
o
set
the
IP
pack
et
t
ran
sf
er
funct
ion
●
CC-Link IE Field Network gateway setting
Through a module, such as an Ethernet adapter module, where the CC-Link IE Field Network gateway setting can be
configured, any IP address can be used for the Ethernet device side. (
Page 158, Section 8.3.4, Page 166, Section
8.3.7 (2)
Note, however, that the network addresses on the CC-Link IE Field Network side must be the same.
For the IP address setting range, refer to the following table.
●
When setting the IP address in each device, do not use the IP addresses already used for other devices.
Device to be set
Setting range of the IP address
First and second octets
Third octet
Fourth octet
Ethernet device
Within the range applicable to the Ethernet device
Module supporting the CC-
Link IE Field Network gateway
setting
Within the range applicable to the module supporting the CC-Link IE Field Network gateway
setting (
Manual for the module supporting the CC-Link IE Field Network gateway
setting used)
Master/local module
0.0 to 255.255
Automatically set (network
number of the own station)
1 to 239
Automatically set (station
number of the own station)
1 to 120
125 (125 is always set
in the master station.)
Universal model QCPU on the
communication route (not
connected to an Ethernet
device)
IP address setting not required
Содержание QJ71GF11-T2
Страница 1: ...MELSEC Q CC Link IE Field Network Master Local Module User s Manual QJ71GF11 T2 ...
Страница 2: ......
Страница 558: ...556 Appendix 12External Dimension Diagram 27 4 23 115 98 4 Unit mm ...
Страница 559: ...557 APPENDICES A Appendix 12 External Dimension Diagram Memo ...
Страница 567: ......