(a) Control data
Device
Item
Setting data
Setting range
Set by
(S1)+0
Execution/
abnormal end type
0000
H
0001
H
0080
H
0081
H
User
1) Execution type (bit 0)
0: Without arrival confirmation
• When the target station is on the same network
The process is completed when data is sent from the own
station.
• When the target station is on another network
The process is completed when data arrives at the relay station
on the same network.
1: With arrival confirmation
The process is completed when data is stored in the specified
channel of the target station.
When "0: Without arrival confirmation" is specified, the result is
regarded as normal on the own station even if the transmission to the
target station fails as follows.
• When communication ends normally even though sent data are
abnormal
• When data cannot be stored in the target station, because
instructions are executed to the same station from multiple stations
(The target station generates an error code (D202
H
or D282
H
))
2) Abnormal end type (bit 7)
Specify the data set status in case of abnormal end.
0: After (S1)+11, no data is set for abnormal end.
1: Data at the time of abnormal end is set in the area starting from
(S1)+11.
(S1)+1
Completion status
The status of when the instruction is ended is stored.
0: Normal
Values other than 0: Error (
System
b15
0
0
2
1
b7
b0
to
to
Completed
Target
station
Request
source
Completed
Target
station
Request
source
Relay
station
Completed
Target
station
Request
source
Relay
station
Target
station
Completed