![Mitsubishi Electric QJ71GF11-T2 Скачать руководство пользователя страница 160](http://html.mh-extra.com/html/mitsubishi-electric/qj71gf11-t2/qj71gf11-t2_user-manual_1811847160.webp)
158
8.3.4
Accessible range
The accessible range differs depending on whether the conditions listed in Page 149, Section 8.3.2 (1) are met or not.
• When one of the Ethernet devices does not have an IP address that does not meet the IP address setting
rules, both of the request source device and request destination device need to be connected to a module,
such as an Ethernet adapter module, supporting the CC-Link IE Field Network gateway setting. Configuring
the CC-Link IE Field Network gateway setting allows communications to be performed. (
Manual for the
module supporting the CC-Link IE Field Network gateway setting used)
• To perform communications between Ethernet devices with an IP address following the setting rules, a
module supporting the CC-Link IE Field Network gateway setting is not required to be connected.
Range of communications of when
and
are Ethernet devices with an IP address that does not meet the IP
address setting rules
Different network addresses
Value other than 1 to 239
Value other than 1 to 120
IP address that does not follow
the IP address setting rules
10 . 11 . 250 . 150
Ex.
3
4
(Modules not supporting the CC-Link IE Field Network
gateway setting)
Ethernet adapter
module 1
Ethernet adapter
module 2
Communications established
(The CC-Link IE Field Network gateway setting is required in the Ethernet adapter modules 1 and 2.)
Ethernet device
where an IP address
meeting the setting
rules has been set
Ethernet device
where an IP address
not meeting the setting
rules has been set
Ethernet device
where an IP address
not meeting the setting
rules has been set
Ethernet device
where an IP address
meeting the setting
rules has been set
Communications
not established
Communications
established
Communications
not established
(Modules supporting the CC-Link IE Field Network
gateway setting)
Содержание QJ71GF11-T2
Страница 1: ...MELSEC Q CC Link IE Field Network Master Local Module User s Manual QJ71GF11 T2 ...
Страница 2: ......
Страница 558: ...556 Appendix 12External Dimension Diagram 27 4 23 115 98 4 Unit mm ...
Страница 559: ...557 APPENDICES A Appendix 12 External Dimension Diagram Memo ...
Страница 567: ......