(b) Example of interlock using devices other than X and Y
The following shows an example of sending data in W0 to W3 of the master station (station No.0) to W1000 to
W1003 of the local station (station No.1). This is a method used when X and Y cannot be used as interlock
devices.
(B0 and B1000 are used for a handshake to the CPU module.)
The send request turns on.
The contents of D0 to D3 are transferred to W0 to W3.
Upon completion of storage in W0 to W3, turn on B0 of the sending station for a handshake.
Cyclic transmission sends signals starting from RWw0 following by signals starting from RWwFE0, and B1000
of the receiving station is turned on.
The contents of W1000 to W1003 are stored in D0 to D3.
Upon completion of storage in D0 to D3, turn on B0 of the receiving station for a handshake.
When B1000 of the sending station turns on, turn off B0 of the sending station.
When B1000 of the receiving station turns off, turn off B0 of the receiving station.
8
1
4
5
2
3
7
6
Cyclic transmission
Link refresh
Send
request
SET B0
RWw0
RWr0
RWrFE0
RWw0
RWr0
RWrFE0
RWwFE0
RWwFE0
W0
B0
B1000
W1000
W0
B0
B1000
W1000
CPU
module
Master
station
CPU
module
Master/local module
Local
station
Master/local module
Send data (W)
Receive data (W)
B1000
Receiving station
Sending station
Master station (Station No.0)
Master station (Station No.0)
Local station (Station No.1)
Local station (Station No.1)
Data flow
Program
Sending station
Receiving station
1
2
3
4
5
6
7
8