CHAPTER 10 DEDICATED INSTRUCTIONS
10
10.
17 G
P
.C
C
PAS
ET
(Set
ting Param
e
te
rs)
10.
17.
2
In
st
ru
ct
ion det
ai
ls
(4) Program example (parameter setting in the master station)
A program example is described below. The program sets parameters to the master station of network number 1
when M171 turns on.
(a) System configuration
The following figure shows a system configuration to set CC-Link IE Field Network parameters for the master
station.
(b) Intelligent function module switch setting
Before executing the CCPASET instruction, set the intelligent function module switches as follows.
Project window
[Parameter]
[PLC Parameter]
"I/O Assignment" tab
Press the
button.
(c) Devices used in the program
Device
Description
Device
Description
M171
Start contact
D2010 to
D2024
Network configuration setting data
M172
Completion device
D2610 to
D2617
Reserved station specification data
M173
Completion status indication device
D2620 to
D2627
Error invalid station setting data
D2000 to
D2003
Control data
Network No.1
CPU module
CCPASET instruction
execution source
(own station)
Device
Master/local module
Parameter settings
Master station (station No.0)
Intelligent device station (Station No.3)
Reserved station
(no actual device connected)
Intelligent device station (station No.2)
Intelligent device station (station No.1)