6. HOMING MODE
6 - 2
(2) Temporary stop/restart
When Halt is switched on during home position return, the servo motor decelerates with being executed
the home position return deceleration time constant ([Pr. PT61 Home position return acceleration time
constant] or [Pr. PT62 Home position return deceleration time constant]), and then stops temporarily.
Turning off Halt again resets the temporary stop without restarting the operation. Turning on Controlword
bit4 (Homing operation start) after the temporary stop is reset restarts the home position return.
Controlword bit4 (Homing operation start) does not function even it is switched on during a temporary
stop.
The temporary stop/restart input functions in the following status.
Operation status
Point table
Jog operation
Home position return
During a stop
Temporary stop
Temporary stop
During acceleration
Temporary stop
Temporary stop
Temporary stop
At a constant speed
Temporary stop
Temporary stop
Temporary stop
During deceleration
Temporary stop
Temporary stop
During a temporary
stop
Restart
Restart
Stop
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...