12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
12 - 59
3) Operation
Selecting DI0 to DI7 for the point table and switching on ST1 starts a forward rotation of the motor
over the travel distance of the position data at the set speed, acceleration time constant and
deceleration time constant.
Switching on ST2 starts a reverse rotation in accordance with the values set in the selected point
table.
When the positioning operation is performed consecutively with the incremental value command
method, the servo motor rotates only in one direction.
To change the travel direction during the continuous operation, perform the operation with the
absolute value command method.
Item
Device to be used
Setting
Automatic operation mode
selection
MD0 (Operation mode selection 1)
Switch on MD0.
Point table selection
DI0 (Point table No. selection 1)
DI1 (Point table No. selection 2)
DI2 (Point table No. selection 3)
DI3 (Point table No. selection 4)
DI4 (Point table No. selection 5)
DI5 (Point table No. selection 6)
DI6 (Point table No. selection 7)
DI7 (Point table No. selection 8)
Refer to section 12.5.2 (1) (b) 2).
Start
ST1 (Forward rotation start)
ST2 (Reverse rotation start)
Switch on ST1 to start.
Switch on ST2 to start.
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...