7. HOW TO USE THE POINT TABLE
7 - 14
(3) Details of the OMS Bit of Statusword (pt mode)
Bit
Symbol
Description
10
Target reached
0: Halt (Bit8) = 0: Target position not reached.
0: Halt (Bit8) = 1: Axis decelerates.
1: Halt (Bit8) = 0: Target position reached.
1: Halt (Bit8) = 1: Velocity of axis is 0.
Judgment condition for Target position reached
This Bit becomes Target position reached when the following conditions are met: (1) the
difference between the current position and the point table command position is equal to or
less than the value set in Position window (6067h), and (2) the time of status (1) is longer
than the time set in Position window time (6068h).
12
Set-point acknowledge
0: Positioning completed (waiting for next command)
1: Positioning being executed
13
Following error
0: No following error
1: Following error
Judgment condition for Following error
When the time set in Following error time out (6066h) elapses in a state that the droop
pulses exceed the value set in Following error window (6065h), this Bit becomes "1".