4. PARAMETERS
4 - 1
4. PARAMETERS
CAUTION
Never make a drastic adjustment or change to the parameter values as doing so
will make the operation unstable.
Do not change the parameter settings as described below. Doing so may cause
an unexpected condition, such as failing to start up the servo amplifier.
Changing the values of the parameters for manufacturer setting
Setting a value out of the range
Changing the fixed values in the digits of a parameter
4.1 Parameter list
POINT
To enable a parameter whose symbol is preceded by *, cycle the power after
setting it. However, the time will be longer depending on a setting value of [Pr.
PF25 Instantaneous power failure tough drive - Detection time] when
"instantaneous power failure tough drive selection" is enabled in [Pr. PA20].
The character strings in the detailed explanation column are shown in this chapter or the following instruction
manual. Refer to the referenced item or the instruction manual.
Character string
Reference
Section 4.2.1 to
4.2.5
Section 4.2.1 to 4.2.5 of this chapter
MR-JE-_C
MR-JE-_C Servo Amplifier Instruction Manual
Network
MR-JE-_C Servo Amplifier Instruction Manual (Network)
Profile
MR-JE-_C Servo Amplifier Instruction Manual (Profile Mode)
4.1.1 Basic setting parameters ([Pr. PA_ _ ])
POINT
In the positioning mode, the following parameter cannot be used.
[Pr. PA05 Number of command input pulses per revolution]
No.
Symbol
Name
Initial
value
Unit
Detailed
explanation
PA01
*STY
Operation mode
1000h
Section 4.2.1
PA02
*REG
Regenerative option
0000h
MR-JE-_C
PA03
*ABS
Absolute position detection system
0000h
PA04
*AOP1 Function selection A-1
2000h
PA05
*FBP
Number of command input pulses per revolution
10000
PA06
CMX
Electronic gear numerator (command pulse multiplication numerator)
1
Section 4.2.1
Number of gear teeth on machine side
PA07
CDV
Electronic gear denominator (command pulse multiplication
denominator)
1
Number of gear teeth on servo motor side
PA08
ATU
Auto tuning mode
0001h
MR-JE-_C
PA09
RSP
Auto tuning response
16
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...