11. APPLICATION OF FUNCTIONS
11 - 7
(c) If the interrupt travel distance is long during deceleration, the servo motor stops with the deceleration
time constant after rotating with the command speed at which TPR1 (Touch probe 1) turned on.
Interrupt positioning travel distance
Speed when TPR1 is on
0.888 ms
Deceleration time constant
(Note)
Servo motor
speed
0 r/min
Forward rotation
Reverse rotation
TPR1
(Touch probe 1)
ON
OFF
Controlword bit 4
(New set-point)
ON
OFF
Note. This is the deceleration time constant of point table at the time of start.
(d) If TPR1 (Touch probe 1) is turned on again during the interrupt positioning, the input is disabled.
Interrupt positioning travel distance
0.888 ms
Deceleration time constant
(Note)
Disabled
Servo motor
speed
0 r/min
Forward rotation
Reverse rotation
TPR1
(Touch probe 1)
ON
OFF
Controlword bit 4
(New set-point)
ON
OFF
Note. This is the deceleration time constant of point table at the time of start.
(5) Using together with other functions
Availability of other functions during the interrupt positioning is as follows.
Function
Availability (Note 1)
S-pattern acceleration/deceleration
Stroke limit
Software limit
Temporary stop/restart
Speed change value
Analog override
(Note 2)
Backlash
Rough match
Electronic gear
Roll feed display function
Touch probe 1 detection function (current
position latch function)
Note 1.
: enabled, : disabled, : enabled with condition
2. Enabled only in a constant speed.
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...