9. HOW TO USE JOG MODE
9 - 2
(2) Station JOG operation in the indexer method
(a) Setting
Set objects/registers and parameters as shown below according to the purpose of use. In this case,
"Target point table" is disabled.
Item
Object/register/parameter to be used
Setting
Selecting Jog mode (jg)
Modes of operation
Set "-100".
Station JOG operation
selection
[Pr. PT27]
Select "_ _ 0 _" (Station JOG operation).
Servo motor speed
Profile velocity
Set the servo motor speed.
Acceleration time constant
Profile Acceleration
Set the acceleration time constant.
Deceleration time constant
Profile deceleration
Set the deceleration time constant.
Speed limit
Max profile velocity
Set a speed limit value in operation.
(b) Setting assignment direction of station No.
Select an assignment direction of station No. with [Pr. PA14].
CW
CCW
[Pr. PA14] setting
Assignment direction of station No.
0
Next station No. is assigned in CW direction in order of 1, 2,
3…
1
Next station No. is assigned in CCW direction in order of 1,
2, 3…
Station No.
1
2
3
4
CW direction
Station No.
1 2
3 4
CCW direction
[Pr. PA14]: 0 (initial value)
[Pr. PA14]: 1
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...