8. HOW TO USE INDEXER
8 - 9
Index
Sub
Name
Data
Type
Access
Default
Description
607Fh
Max profile velocity
U32
rw
2000000
Maximum speed
Unit: Vel unit (0.01 r/min)
6080h
Max motor speed
U32
rw
Servo motor maximum speed
Unit: r/min
6081h
Profile velocity
U32
rw
10000
Speed after acceleration completed
Unit: Vel unit (0.01 r/min)
6083h
Profile acceleration
U32
rw
0
Acceleration at start of movement to target
position
Unit: ms
6084h
Profile deceleration
U32
rw
0
Deceleration at arrival at target position
Unit: ms
6085h
Quick stop
deceleration
U32
rw
100
Deceleration time constant for Quick stop
Unit: ms
6091h
0
Gear ratio
U8
ro
2
Gear ratio
1
Motor revolutions
U32
rw
1
Number of gear teeth on machine side
2
Shaft revolutions
U32
rw
1
Number of gear teeth on servo motor side
6092h
0
Feed constant
U8
ro
2
Travel distance per revolution of an output
shaft
1
Feed
U32
rw
[Pr. PT28]
Travel distance setting
2
Shaft revolutions
U32
rw
1
Number of servo motor shaft revolutions
60A8h
SI unit position
U32
rw
00000000h
SI unit position
00000000h (no unit)
60A9h
SI unit velocity
U32
rw
FEB44700h
SI unit velocity
FEB44700h (0.01 r/min)
60E0h
Positive torque limit
value
U16
rw
10000
Torque limit value (forward)
Unit: 0.1% (rated torque of 100%)
60E1h
Negative torque limit
value
U16
rw
10000
Torque limit value (reverse)
Unit: 0.1% (rated torque of 100%)
60F4h
Following error actual
value
I32
ro
Droop pulses (Pos units) (Note)
60FAh
Control effort
I32
ro
0
Position control loop output (speed command)
Unit: Vel unit (0.01 r/min)
2D60h
Target point table
I16
rw
Point table command
Set next station No.
0 to 254: Positioning operation to specified
stations
2D68h
Point demand value
I16
ro
Point table demand
The currently specified next station No. is
returned.
While the servo motor is stopped, the value is
the setting value of the Target point table
(2D60h).
2D69h
Point actual value
I16
ro
Current point table
The completed point table is returned. The
previous value is held until the operation
completes.
2D6Ah
M code actual value
U8
ro
Current M code
In the indexer method, the value is "0".
2D6Bh
Torque limit value2
U16
rw
10000
Torque limit value 2
Unit: 0.1% (rated torque of 100%)
Set a torque limit value in stop.
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...