11. APPLICATION OF FUNCTIONS
11 - 3
1) When the roll feed display is disabled ([Pr. PT26]: _ _ 0 _)
Set the valid range with the distance from the home position.
When the starting position is at 100000, [Pr. PC66] and [Pr. PC67] are set to 500000, and [Pr.
PC68] and [Pr. PC69] are set to 300000, the valid range is between the actual current position of
300000 and 500000 as set in the parameters.
100000
90000
Lower limit value
Upper limit value
300000
500000
0
Home
position
Start
position
Target position
Actual current
position
2) When the roll feed display is enabled ([Pr. PT26]: _ _ 1 _)
When the roll feed display is enabled, the valid range is calculated as the starting position is 0.
Set the valid range with the travel distance from the starting position.
When the starting position is at 100000, [Pr. PC66] and [Pr. PC67] are set to 500000, and [Pr.
PC68] and [Pr. PC69] are set to 300000, the valid range is between the feed current position of
300000 and 500000 from the start position (between the actual current position of 400000 and
600000).
100000
90000
Lower limit value
Upper limit value
300000
500000
0
Home
position
Start position
Target position
Actual current position
400000
600000
80000
0
Feed current position
(4) Timing chart
Device falling position data
TPR1 (Touch probe 1)
TPR1H
(Touch probe 1 rising latch
completed)
TPR1L
(Touch probe 1 falling latch
completed)
Device rising position data
Current position data
Within 5 ms (Note 1)
Within 5 ms (Note 1)
Within 3 ms
Within 3 ms
0
A
E
0
B
F
A
B
E
F
ON
OFF
ON
OFF
ON
OFF
Latch data range
Upper limit value
Latch data range
Lower limit value
0.4 ms or longer
Disabled
(Note 2)
Disabled
(Note 2)
Not changed
Not changed
C
D
(Note 3)
Note 1. When TPR1 (Touch probe 1) is assigned to the CN3-6 pin or CN3-19 pin with [Pr. PD24] or [Pr. PD27], a current position data
can be obtained in high speed (within 0.4 ms). When assigning TPR1 to the CN3-6 pin or CN3-19 pin, set the touch probe
input signal filter in [Pr. PD41].
2. The position data is not changed from the previous value.
3. TPR1H (Touch probe 1 rising latch completed) turns off at the same timing as TPR1L (Touch probe 1 falling latch completed)
turns on. Set as TPR1L turns on/off within the range of the latch data.
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...