8. HOW TO USE INDEXER
8 - 4
No. Start-up sequence
Fault
Investigation
Possible cause
Reference
5
Gain adjustment
Rotation ripples (speed
fluctuations) are large
at low speed.
Make gain adjustment in the
following procedure.
1. Increase the auto tuning
response level.
2. Repeat acceleration and
deceleration several times to
complete auto tuning.
Gain adjustment fault
MR-JE-_C
Chapter 6
Large load inertia
moment causes the
servo motor shaft to
oscillate side to side.
If the servo motor can be run
safely, repeat acceleration and
deceleration three times or more
to complete auto tuning.
Gain adjustment fault
MR-JE-_C
Chapter 6
Note. Refer to "MELSERVO-JE Servo Amplifier Instruction Manual (Troubleshooting)" for details of alarms and warnings.
8.2 Function explanation
POINT
When the same next station No. is specified as station No. of the current
position, and the positioning operation is executed, the motor does not start
because the travel distance is determined as "0".
In the indexer method, "Touch probe function" is disabled.
In the indexer method, "Position actual value", "Touch probe status", "Touch
probe pos1 pos value", "Touch probe pos1 neg value", "Touch probe pos2 pos
value" and "Touch probe pos2 neg value" will be always 0.
The setting value of the Torque limit value2 (2D6Bh) is automatically enabled
depending on the operation status. As the initial value of the Torque limit value 2
(2D6Bh) is 0.0%, when using the indexer operation, change the Torque limit
value 2 (2D6Bh) from the initial value. If the value remains unchanged, the servo
motor coasts.
8.2.1 Indexer mode (idx)
(1) Logic of indexer
The circumference of the load side (360 degrees) can be divided into a maximum of 255 stations.
Positioning is executed to a station selected with "Target point table". The following diagram is an
example for when [Pr. PA14] is set to "0".
Station No. 0
Station No. 254
Station No. 253
Station No. 2
Station No. 1
CW direction
The station No. 0 is set as a home position. Set the number of stations with [Pr. PT28].
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...