12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
12 - 67
(d) Temporary stop/restart
When TSTP (Temporary stop/restart) is switched on during JOG operation, the servo motor
decelerates with the deceleration time constant being executed ([Pr. PC02 JOG operation
deceleration time constant]), and then stops temporarily. Turning on TSTP (Temporary stop/restart)
again restarts the servo motor. During a temporary stop, ST1 (Forward rotation start) or ST2
(Reverse rotation start) does not function even if switched on.
In addition, when any of the following conditions is satisfied during a temporary stop, the temporary
stop is reset.
The manual operation mode is switched to the automatic operation mode or homing mode.
The servo amplifier enters the servo-off status.
The stroke limit or software limit is detected.
The temporary stop/restart input functions in the following status.
Operation status
Manual operation
During a stop
Temporary stop
During acceleration
Temporary stop
At a constant speed
Temporary stop
During deceleration
Temporary stop
During a temporary
stop
Restart
(e) Timing chart
ON
OFF
RD (Ready)
ON
OFF
ALM (Malfunction)
ON
OFF
MEND (Travel completion)
CPO (Rough match)
ON
OFF
ON
OFF
SON (Servo-on)
Servo motor
speed
ON
OFF
Forward rotation
0 r/min
Reverse rotation
ON
OFF
ON
OFF
80 ms
Forward rotation JOG
Reverse rotation JOG
ST1 (Forward rotation start)
ST2 (Reverse rotation start)
MD0
(Operation mode selection 1)
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...