4. PARAMETERS
4 - 31
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
General
purpose
Communication
CP
PS
CP
PS
PD31
*DO3
Output device
selection 3
_ _ x x Device selection
Optional output device can be assigned to the CN3-16 pin.
In the initial setting, since the OP signal is assigned to CN3-16 pin in "OP
signal assignment selection" of [Pr. PD38], the output device cannot be
assigned with this parameter. To assign output devices, select a value
other than "CN3-16 (3 _ _ _)" (initial value) in "OP signal assignment
selection" of [Pr. PD38].
Refer to table 4.3 in [Pr. PD29] for setting value.
00h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
PD32
*DO4
Output device
selection 4
_ _ x x Device selection
Optional output device can be assigned to the CN3-22 pin.
When "CN3-22 (4 _ _ _)" is selected in "OP signal output selection" of
[Pr. PD38], this digit is disabled and OP (Encoder Z-phase pulse (open
collector)) is assigned to the CN3-22 pin.
Refer to table 4.3 in [Pr. PD29] for setting value.
04h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
PD35
*DOP1
Function
selection D-1
_ _ _ x Stop method selection for when either the LSP (Forward rotation stroke
end) or the LSN (Reverse rotation stroke end) is off.
Select a stop method for when the either LSP (Forward rotation stroke
end) or the LSN (Reverse rotation stroke end) is off. (Refer to section 4.5.)
1h
Setting value
Control mode
CP
PS
0
Quick stop
1
Slow stop
2
Slow stop
(deceleration to a stop
by deceleration time
constant)
Slow stop
3
Quick stop
(stop by clearing
remaining distance)
Quick stop
_ _ x _ Base circuit status selection for RES (Reset) on
0: Base circuit shut-off
1: No base circuit shut-off
0h
_ x _ _ Stop method selection at software limit detection
Select a stop method at software limit detection. (Refer to section 4.6.)
0: Quick stop
1: Slow stop
2: Slow stop (deceleration to a stop with deceleration time constant)
3: Quick stop (stop by clearing remaining distance)
1h
x _ _ _ For manufacturer setting
0h
PD41
*TPOP
Touch probe
function
selection
_ _ _ x For manufacturer setting
0h
_ _ x _ Touch probe signal filter selection
0: None
1: 0.111 ms
2: 0.222 ms
3: 0.444 ms
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...