9. HOW TO USE JOG MODE
9 - 10
9.2 Manual pulse generator operation
(1) Setting
POINT
To enhance noise tolerance, set [Pr. PA13] to "_ 2 _ _" when the command
pulse frequency is 500 kpulses/s or less, or set [Pr. PA13] to "_3_ _" when the
command pulse frequency is 200 kpulses/s or less.
For the Jog mode (jg) in the indexer mode, the manual pulse generator
operation cannot be used.
According to the purpose of use, set input devices and parameters as shown below. In this case, Target
point table (2D60h) is disabled.
Item
Device/parameter to be used
Setting
Manual operation mode
selection
Modes of operation (6060h)
Set "-100".
Manual pulse generator
multiplication
[Pr. PT03]
Set the multiplication factor for the pulses
generated from the manual pulse generator.
For details, refer to (3) in this section.
Servo motor rotation direction [Pr. PA14]
Refer to (2) in this section.
Command input pulse train
input form
[Pr. PA13]
Set "_ _ _ 2" (A/B-phase pulse train).
Pulse train filter selection
[Pr. PA13]
Set other than "_ 0 _ _" and "_ 1 _ _".
(2) Servo motor rotation direction
[Pr. PA14] setting
Servo motor rotation direction
Manual pulse generator operation:
forward rotation
Manual pulse generator operation:
reverse rotation
0
CCW rotation
CW rotation
1
CW rotation
CCW rotation
CW
CCW
Forward rotation
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...