12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
12 - 62
b) Incremental value command method ([Pr. PT01] = _ _ _ 1)
The position data of the incremental value command method is the sum of the position data of
consecutive point tables.
The following shows how to set.
Point table setting
Dwell
Auxiliary function
1 or more
1
Positioning in a single direction
The following shows an operation example with the set values listed in the table below.
Point table No.
Position data
[10
STM
μm]
Servo motor
speed [r/min]
Acceleration
time constant
[ms]
Deceleration
time constant
[ms]
Dwell [ms]
Auxiliary
function
M code
1
5.00
3000.00
100
150
100
1
5
2
6.00
2000.00
150
200
200
1
10
3
3.00
1000.00
300
100
Disabled
0 (Note)
15
Note. Be sure to set "0" to the auxiliary function of the last point table of the consecutive point tables.
Servo motor speed
Forward rotation
0 r/min
Reverse rotation
Position address
Point table No. to select
ST1 (Forward rotation start)
(Note 1)
ON
OFF
PT0 (Point table No. output 1)
to PT7 (Point table No. output 8)
(Note 2)
Speed
(3000.00)
Acceleration/deceleration time
constant of point table No. 1
Acceleration/deceleration time
constant of point table No. 2
Speed
(2000.00)
Speed (1000.00)
Acceleration/deceleration time
constant of point table No. 3
6.00
0
5.00
11.00
14.00
1
1
M code actual value
05
3.00
Note 1. Switching on ST2 (Reverse rotation start) starts positioning in the reverse rotation direction.
2. Up to four points of DO are available; therefore, PT0 to PT7 cannot be outputted simultaneously.
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...