12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
12 - 60
(c) Automatic operation timing chart
1) Automatic individual positioning operation
a) Absolute value command method ([Pr. PT01] = _ _ _ 0)
While the servo motor is stopped under servo-on state, switching on ST1 (Forward rotation
start) starts the automatic positioning operation.
The following shows the timing chart.
MD0
ON
OFF
ON
OFF
SON (Servo-on)
ON
OFF
ST1
(Forward rotation start)
ST2
(Reverse rotation start)
ON
OFF
Point table No.
Forward
rotation
Servo motor speed
ON
OFF
INP (In-position)
ON
OFF
CPO (Rough match)
MEND
(Travel completion)
ON
OFF
PT0 (Point table No.
output 1) to PT7 (Point
table No. output 8)
(Note 2)
M code output (Note 3)
ON
OFF
RD (Ready)
ALM (Malfunction)
ON
OFF
3 ms or longer
3 ms or longer
Point table No. 1
Point table No. 2
1
2
1
2
M code of point table No. 1
3 ms or shorter
5 ms or longer
5 ms or longer
(Operation mode
selection 1)
Reverse
rotation
0 r/min
(Note 1)
Note 1. The detection of external input signals is delayed only by the time set in the input filter setting of [Pr. PD29].
Considering the output signal sequence from the controller and change in signal variations due to hardware,
configure a sequence that changes the point table selection earlier.
2. Up to four points of DO are available; therefore, PT0 to PT7 cannot be outputted simultaneously.
3. M code can be read with M code actual value (2D6Ah).
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...