4. PARAMETERS
4 - 9
No.
Symbol
Name
Initial
value
Unit
Detailed
explanation
PF16
For manufacturer setting
0000h
PF17
10
PF18
0000h
PF19
0000h
PF20
0000h
PF21
DRT
Drive recorder switching time setting
0
[s]
MR-JE-_C
PF22
For manufacturer setting
200
PF23
OSCL1 Vibration tough drive - Oscillation detection level
50
[%]
MR-JE-_C
PF24
*OSCL2 Vibration tough drive function selection
0000h
PF25
CVAT
Instantaneous power failure tough drive - Detection time
200
[ms]
PF26
For manufacturer setting
0
PF27
0
PF28
0
PF29
0000h
PF30
0
PF31
FRIC
Machine diagnosis function - Friction judgment speed
0
[r/min]
MR-JE-_C
PF32
For manufacturer setting
50
PF33
0000h
PF34
0000h
PF35
0000h
PF36
0000h
PF37
0000h
PF38
0000h
PF39
0000h
PF40
0
PF41
0
PF42
0
PF43
0
PF44
0
PF45
*FOP12 Function selection F-12
0000h
Network
PF46
MIC
Modbus RTU communication time out selection
0
[s]
PF47
For manufacturer setting
0000h
PF48
0000h
4.1.7 Positioning control parameters ([Pr. PT_ _ ])
POINT
In the positioning mode, the following parameter cannot be used.
[Pr. PT49 Torque slope]
[Pr. PT52 Speed limit]
[Pr. PT63 Zero speed 2 level]
[Pr. PT64 Zero speed 2 filtering time]
[Pr. PT67 Speed reached 2 output range]
[Pr. PT68 Speed reached 2 filtering time]
No.
Symbol
Name
Initial
value
Unit
Detailed
explanation
PT01
*CTY
Command mode selection
0300h
Section 4.2.4
PT02
*TOP1 Function selection T-1
0001h
PT03
*FTY
Feeding function selection
0000h
PT04
For manufacturer setting
0000h
PT05
ZRF
Home position return speed
100.00
[r/min]
Section 4.2.4
PT06
CRF
Creep speed
10.00
[r/min]
Содержание MR-JE-C
Страница 33: ...2 SIGNALS AND WIRING 2 16 MEMO ...
Страница 37: ...3 STARTUP 3 4 MEMO ...
Страница 129: ...6 HOMING MODE 6 36 MEMO ...
Страница 169: ...7 HOW TO USE THE POINT TABLE 7 40 MEMO ...
Страница 203: ...9 HOW TO USE JOG MODE 9 12 MEMO ...
Страница 215: ...11 APPLICATION OF FUNCTIONS 11 8 MEMO ...
Страница 307: ...12 WHEN USING WITH A GENERAL PURPOSE INTERFACE 12 92 MEMO ...
Страница 309: ...MEMO ...